tip manufacture refraction instruments, ophthalmic diagnostic instruments, visual acuity chart, ophthalmic unit, electric table,one stop medical instrument

Linear Mirror Binocular Status Check Eye Position Screening Vision Examination Inhibition Monocular Retinal Deviatio

Sku. 195511
$ 95 $ 0.000 save   $0.00
Quantity:
- +
piece(s)
Stock:
3 in Stock
Shipping:
$ 34.8
Can't deliver
To Be Negotiated
to United States Change
Estimated delivery time : 0-27 working days. See details
Total Price:
$ 95 $ 0.00 (Save and Extra $0.00 )

Shipping calculated at checkout.

Buy Now
Add to Cart
This item is collected in wish list
Linear Mirror Binocular Status Check Eye Position Screening Vision Examination Inhibition Monocular Retinal Deviatio

Linear Mirror Binocular Status Check Eye Position Screening Vision Examination Inhibition Monocular Retinal Deviatio

Linear Mirror Binocular Status Check Eye Position Screening Vision Examination Inhibition Monocular Retinal Deviatio

Requirement Details

Your message must be between 20-3,000 characters!

Email

Check your email

Phone

Check your phone number

Submit Requirement
Features:
Bagolini Line-Shaped Mirror Product Introduction:

For ophthalmologists to examine the state of binocular vision function, it can quickly determine whether it is normal, or whether
there is retinal correspondence or abnormal correspondence that is inhibited, and the location of inhibition. The examination purpose includes testing for binocular fusion function, normal retinal correspondence and abnormal correspondence, single eye inhibition, dominant eye testing, and nystagmus testing Bagolini Line-Shaped Mirror Examination Method: The line-shaped mirror is etched with many very fine oblique parallel lines. The lines on the two spectacle lenses are perpendicular to each other. If the line direction on the spectacle lens of the right eye is 45 degrees, the line direction on the spectacle lens of the left eye is 135 degrees. When the patient looks through the lens at a light source, they will see a line of light that is vertical to the line-shaped mirror,the right eye sees a 135 degree line of light and the left eye sees a 45 degree line of light. In the condition of bright room or semi-dark room, the examiner places the Bagolini spectacles before the patient's two eyes and asks the patient to look at a point light source 33cm away and 6 meters away. The examiner observes the results seen by the patient and understands their binocular vision function state based on it.
The patient looks through the lens at the point light source, and the bright line seen by them is shown in the following figure:
A. Normal retinal correspondence with no apparent eye position deviation, or harmonious abnormal retinal correspondence
B. Inhibited central retinal field of the right eye, commonly seen in abnormal corresponding internal deviation
C. Massive inhibition of the right eye, commonly seen in abnormal corresponding external deviation
D. Double vision. It is seen in cases of evident internal deviation, indicating normal retinal correspondence
E. Double vision. It is seen in cases of evident external deviation, indicating normal retinal correspondence
F. Double vision. It is seen in cases of vertical deviation, indicating normal retinal correspondence
G. Inhibited central retinal field and surrounding area of the left eye. It is commonly seen in cases where there is evident
deviation within a few months after birth
H. Alternating external deviation, commonly seen in cases of binocular vision balance
I . Uniocular constant external deviation (right eye external deviation, vision is lower)
Linear Mirror Binocular Status Check Eye Position Screening Vision Examination Inhibition Monocular Retinal Deviatio
Linear Mirror Binocular Status Check Eye Position Screening Vision Examination Inhibition Monocular Retinal Deviatio
Linear Mirror Binocular Status Check Eye Position Screening Vision Examination Inhibition Monocular Retinal Deviatio
Linear Mirror Binocular Status Check Eye Position Screening Vision Examination Inhibition Monocular Retinal Deviatio
Payment & Delivery
Linear Mirror Binocular Status Check Eye Position Screening Vision Examination Inhibition Monocular Retinal Deviatio
Ask a Question
No data
Customer reviews
Your reviews :
Share your thoughts with other customers
0/1000

Please write a review with more than 10 characters.

Allowed file types: JPG, JPEG, PNG, GIF.
Anonymity
No data

Processing time


According your order list. we will supply  delivery time .

 

Commonly is 5-7 work days after we confirm payment

 

Shipping time


By Express :  3-7 days . Door to door service

 

By Air : 3-7 days . (the goods arrival at your local air ports 

 

By sea : 30-40 days  (the goods arrival at your local sea ports )


PS : by air or by sea, if you need door to door service, please tell us . we will help you checking the extra door to door cost.

 

How many months warranty do you provide ?

one year

 

What should I do if the machine have question ?

For ensuring all the items are in good quality, we will test all products before the packages were sent out. Once the machine have some question, please don't worry.  kindly send us some images of the situation , Video and machine series, and explain the question in where . we will supply solution to you deal soon.

 

What should I do if the spare parts is broken in Warranty  ?

If in Warranty, some spare parts broken in the Use.  kindly supply picture or video , and machine series number .

 

We will send the spare parts by express to you soon.. and we bear express cost .

 

 

Please enter your target price

Please provide a quantity

United States

Please provide your name

Please enter your email adress

Enter a valid email address

+

Please enter the phone number

Please enter the inquiry information

Submit
YOU MAY LIKE
Inquiry Sent Successfully
We will contact you within 24 hours via the following email
OK